0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter

Product Details
Customization: Available
Application: Power
Phase: Single
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
to see all verified strength labels (27)
  • 0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
  • 0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
  • 0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
  • 0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
  • 0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
  • 0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
GBK
Core
Core-type Transformer
Cooling Method
Nature Cooling
Winding Type
Two-winding Transformer
Certification
ISO9001, CE
Usage
Single-phase Transformer, Power Transformer
Frequency Characteristics
Low Frequency
Shape of Core
Ring
Brand
Zhengxi
Adjust Time
<1s
Input Voltage
220V AC
Output Voltage
220V
Capacity
500va
Plug and Socket
Us EU Cn Au Please Note When Order
Power Factor
0.8
Certificate
CE/Is09001
Transport Package
Export Standard Packing
Specification
240*310*263mm
Trademark
ZHENGXI or OEM
Origin
Zhejiang, China
HS Code
8504319000

Product Description

General
¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯

The isolation transformer refers to the transformer whose input winding is electrically isolated from the output winding. The isolation transformer is used to avoid accidental simultaneous contact with the charged body. The isolation of the transformer is to isolate the current of the primary and secondary coils; it is widely used in industrial and mining enterprises and the electronics industry and precision instruments. Equipment, medical equipment, machine tools and machinery; high-insulation strength between the primary and secondary winding to isolate different potentials to suppress common mode interference. With the development of industry, the industrial pollution brought to the power grid is becoming more and more serious. These pollution mainly come from industrial equipment (such as electric motors, electric welders, etc.) and mechanical switching transients, lightning strikes, corona, passing cars. Ignition, radio and television transmission, etc. Although this kind of clutter has no effect on general-purpose equipment, it has serious impact on equipment systems such as precision measurement and remote control, digital data processing equipment, information communication systems and computer networks.

Production Function
¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯
The main function of the isolation transformer is to completely insulate the electrical of the primary side from the secondary side and also isolate the circuit. In addition, the high-frequency loss of the iron core is utilized to suppress high-frequency clutter from being transmitted to the control loop. The isolation transformer is used to suspend the second ground to the ground, and can only be used in the case where the power supply range is small and the line is short. At this point, the system's capacitance to ground capacitance is not small enough to cause personal injury. Another important role is to personal safety and isolate dangerous voltages.

Date data sheet
¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯
Capacity
500va-5000va
Input voltage
single phase 220V AC
Output voltage
single phase 220v AC Insulation
Rated current
2.28A
Load
≤500va
Class
Class F
Frequency:
50/60HZ
Power frequency withstand voltage:
2500V 1min without breakdown
Insulation resistance
≥5MΩ
Working temperature
upper limit 40 ° C, lower limit -20 ° C
Relative humidity
no more than 90%
Altitude
no more than 2000m
Product Description
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
Company Profile
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
0.2-5kVA Single Phase AC LCD Isolation Dry Type Transformer Voltage Converter
FAQ
 
Q1: What is the Guarantee?
A1: Within One Year From The Sale Date, If There Are Any Accessory Problems,You Just Provide The Photos Of Damaged Accessory, Then We Will Provide Free Accessory.According To The Number Of Products, We Will Provide Easily Damaged Accessories For Free.We Also Can Provide Technical Support If You Need.

Q2: Can we put/show our own Logo on your products?
A2: Yes, no problem, however, the quantity should be a bit big.

Q3: Is OEM/ODM available?
A3: Yes, It Is! Our Products Can Be Customized.We Design And Produce All Kinds Of Automatic Voltage Regulators/Stabilizers According To Our Customers' Specific Requirements.

Q4: What is the MOQ?
A4: For the small capacity products (Automatic Voltage Regulators/Stabilizers) of the default configuration, it is 10 sets. For the big capacity products, it is 1 set.

Q5: Can you offer Form A or Form E or C/O ?
A5: Yes, no problem, we can apply for it from our local government.

Q6: What kind of Certificates do you have?
A6: CE, ISO9001 and SGS.

Q7: What is the Terms of Payment?
A7: L/C, T/T, D/P, D/A, Western Union and MoneyGram (for Small-amount payment).