Customization: | Available |
---|---|
Nature of Source Flow: | Passive inverter |
Certification: | CCC, CE |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | RSP-300W | ||
Rated Power | 300W | ||
Peak power | 600W | ||
Input Voltage | 12V/24V/48V | ||
Output voltage | 100-120V or 220V-240V,50Hz or 60Hz | ||
Output waveform | Pure sine wave inverter | ||
USB port | 5V,2.1A | ||
Waveform distortion | THD < 3% (Linear load) | ||
Conversion efficiency | 90% | ||
Product dimensions | 19.5*11*5.5cm | ||
NET/gross weight of product | 0.85kg,1.05kg | ||
Quantity/weight packed | 12 units,13.2kg | ||
Packing size | 38.5*31.5*37.5cm | ||
Voltage Range | (12V)9.55-15.5V | (24V)19.8-30.27V | (48V)40.2-60.4V |
Under-pressure alarm | (12V)10.5±0.5V | (24V)21V±0.5V | (48V)42V±1V |
Under-voltage protection | (12V)9.5±0.5V | (24V)20V±0.5V | (48V)40V±1V |
Under-pressure recovery | (12V)13±0.5V | (24V)24V±0.5V | (48V)48V±1V |
High Voltage Alarm | (12V)15.5±0.5V | (24V)31V±0.5V | (48V)61V±1V |
High pressure recovery | (12V)14.8±0.5V | (24V)29.5±0.5V | (48V)59V±1V |
Display options | High-definition LED digital display, liquid crystal display, no display | ||
LED indicator light | Blue Light (AC output normal) ; red light flashing (undervoltage/overvoltage, overload, high temperature, short circuit) | ||
Protection function | Undervoltage/overvoltage, overload, high temperature, ac short circuit protection (positive and negative wiring protection-replace the insurance) | ||
Fuse | DC short circuit protection | ||
Circuit topology | High frequency chain | ||
Cooling mode | Intelligent air-cooled, built-in heat sink |